Relay

Inquiry List (0)

Schneider RM Control Relay

  • Brand
    Schneider
  • ID

    Schneider 3 phase Zelio RM 24V 5A 8A Detection Module DC Voltage Control Relay

  • Features
    All Industries > Electrical Equipment & Supplies > Industrial Controls > Relays
  • Specifications

     

    5a 8a control relay module 24vdc zelio dc voltage controlled relay

    schneider 24v 1c/o IP20 IP40 IP50 3 phase voltage control relay

    schneider 2c/o resistive probes 24-480VAC detection dc relay control

Drag
 
 
 
Why Choose Schneider Control Relay
 
FEATURES
 
  • Compliant with international standards EN60255-1, IEC60255-1
  • Wide monitoring parameters: phase,current, voltage, liquid level, frequency, speed, temperature and pump control.
  • DIN rail mount with 3 form factors:17.5mm, 22.5mm and 35mm width
  • Self-powered available for 3 phase range, wiring saving
  • Single or Multifunction available
  • Positive logic output to protect the system at power lose
  • Adjustable time delay to prevent nuisance tripping
  • True RMS value measurement (even on deformed sinus waves)
     
BENEFITS
 
  • Simple and accurate adjustments to achieve quick setup.
  • Innovative: dial pointer LED indicator and” Diagnostic Button” to assist commissioning and troubleshooting
  • Easy setting: QR code on the product to download instruction sheet
  • Robust performance and accurate monitoring
     
 
APPLICATIONS
 
  • Hoisting: construction cranes, Harbor
  • Packaging: Motor voltage, current over load
  • Lifts: construction lifts, passenger lifts, escalators
  • Textile: motor voltage, current overload
  • Water: liquid level at WWW recycling plant on water tank
     
     
     
     
How Is Control Relay Specification
 
RM17TE00
 
RM17TG00
 
 
RM17UB310
 
range of product
Zelio Control
product or component type
Modular measurement and control relays
relay type
Level control relay
relay name
RM22L
relay monitored parameters
Detection by resistive probes
time delay type
Without
switching capacity in VA
2000 VA
measurement range
5...100 kOhm
reset time
1750 ms
maximum switching voltage
250 V AC
minimum switching current
10 mA at 5 V DC
maximum switching current
8 A AC
[Us] rated supply voltage
24...240 V AC/DC 50/60 Hz
supply voltage limits
20.4…264 V AC/DC
operating limits
- 15 % + 10 % Un
power consumption in VA
5 VA AC
maximum power consumption in W
1.5 W DC
output contacts
2 C/O
nominal output current
8 A
run-up delay at power-up
0.6 s
maximum electrode voltage
12 V AC
maximum electrode current
1 mA
repeat accuracy
+/- 2 % for time delay
measurement error
< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
sensitivity scale
5...100 kOhm St (Standard Sensitivity)
sensitivity adjustment
5…100 %
maximum supply current for sensors
1 mA
maximum cable distance between devices
1000 m between probe and delay
cable capacitance
1 nF at HS (High Sensitivity) for probe cable
2.2 nF at St (Standard Sensitivity) for probe cable
4.7 nF at LS (Low Sensitivity) for probe cable
overvoltage category
III conforming to IEC 60664-1
insulation resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
insulation
Between supply and measurement
mounting position
Any position
connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
tightening torque
0.6…1 N.m conforming to IEC 60947-1
housing material
Self-extinguishing plastic
status LED
LED (yellow)relay ON:
LED (green)power ON:
mounting support
35 mm DIN rail conforming to EN/IEC 60715
electrical durability
100000 cycles
mechanical durability
10000000 cycles
utilisation category
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
safety reliability data
B10d = 120000
MTTFd = 125.5 years
contacts material
Cadmium free
width
22.5 mm
net weight
0.1 kg
immunity to microbreaks
100 ms DC
90 ms AC
electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
standards
EN/IEC 60255-1
product certifications
GL
RCM
CCC
CSA
UL
China RoHS
EAC
CE
ambient air temperature for storage
-40…70 °C
ambient air temperature for operation
-20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC
relative humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
vibration resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
shock resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
pollution degree
3 conforming to IEC 60664-1
dielectric test voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
 
RM35UB330
 
  
 
 
 
 
 
 
 

 

 

100% Certified Products 

100% Quality Products 

100% New Products

 

 
 
  
 
Our Company
 
 
Packing & Delivery
Our Service
 

 

100% Certified Products 

100% Quality Products 

100% New Products

 
 

 

 
Kaohsiung Corporation
No.1, Anlin Rd., Yanchao Dist., Kaohsiung 824, Taiwan
Tel:886-7-616-7936   Fax:886-7-616-2831
E-mail:rstitd@rstpower.com.tw
Taipei Office
3F., No. 87-1, Sec. 3, Zhongyang Rd., Tucheng Dist., New Taipei City 236 , Taiwan
Tel:886-2-22677936
Fax:886-2-22687936
Taichung Office
Tel:886-4-23507936
Fax:886-4-23507923